Signet 2850 Conductivity Sensor Manual
Signet 2850 Conductivity Sensor Manual. • the conductivity sensor provided with integral systems will have its custom cell constant information programmed into the electronics at the factory to provide a 2% sensor accuracy. We are the trusted suppliers for georg fischer / gf signet in zimbabwe across harare, bulawayo, chitungwiza, mutare, epworth, gweru, kwekwe, kadoma, masvingo, chinhoyi available in various configurations for maximum installation flexibility
See section 8 for details. Digital (s3 l) or 4 to 20 ma. All 2850 units are built with nema 4x/ip65 enclosures which allow output wiring connections with long cable runs of up to 305 m (1,000 ft).
See Section 8 For Details.
Conductivity test solution values for simple fi eld calibration. • the conductivity sensor provided with integral systems will have its custom cell constant information programmed into the electronics at the factory to provide a 1% sensor accuracy. Npt or iso threads signet 2850 conductivity system or 2850 system overview universal mount all sold separately
• The Conductivity Sensor Provided With Integral Systems Will Have Its Custom Cell Constant Information Programmed Into The Electronics At The Factory To Provide A 2% Sensor Accuracy.
Digital (s3 l) or 4 to 20 ma. • the conductivity sensor provided with integral systems will have its custom cell constant information programmed into the electronics at the factory to provide a 2% sensor accuracy. The 2850 is ideal for applications with a conductivity range of 0.055 to 200,000 ?s or a resistivity range of 18.2 m?
Failure To Follow All Warnings May Lead To Equipment Damage, Injury, Or Death Personal Protective Equipment (Ppe)
All 2850 units are built with nema 4x/ip65 enclosures which allow output wiring connections with long cable runs of up to 305 m (1,000 ft). Be the first to review this product. See page 6 for details.
And Can Power Certain Sensors On Loop Power (See Note On Pg.
Npt or iso threads all sold separately * if the 2850 is used with the 9900, it is not necessary to use the 9900 conductivity module. Shop for the gf signet 2850 conductivity / resistivity sensor and other conductivity sensors at instrumart And can power certain sensors on loop power (see note on pg.
We Are The Trusted Suppliers For Georg Fischer / Gf Signet In Zimbabwe Across Harare, Bulawayo, Chitungwiza, Mutare, Epworth, Gweru, Kwekwe, Kadoma, Masvingo, Chinhoyi Available In Various Configurations For Maximum Installation Flexibility
If the electrode is mounted vertically in a tee, do not recess the electrode orifi ces inside the tee. Failure to follow all warnings may lead to equipment damage, injury, or death personal protective equipment (ppe) always utilize the most appropriate ppe during installation and service of signet products. The 2850 has a limited sensor cable input length of 4.6 m (15 ft).